CRF 06 ** 00 1
18.7
34.7
7/8"-14UNF
Ø17.47
Ø15.87
45.714.8
60.5
Ø 25.7
4.8
1
3
ØX
27
2
FLOW CONTROL VALVES
PRIORITARY FLOW CONTROL VALVE
HYDRAULIC SYMBOL
HYDRAULIC FEATURES
Max. working pressure
210 bar
P of regulation 6.1 ÷ 6.7 bar
Input max. Flow 50 l/min
Control max. Flow 17 l/min
Hydraulic fluid
DIN 51524 Mineral oils
Fluid viscosity
10 ÷ 500 mm
2
/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamin. level class with filter ISO 4406:1999 - class 19/17/14
Weight 0.2 kg
Tightening torque 30 ÷ 40 Nm
Cavity (7/8 - 14 UNF)
CD019006 (See section 15)
CRF = Prioritary flow control valve
Series
Size
06 = 7/8 - 14 UNF
00 = No variants
FLOW CONTROLLED
Variants
Flow
ORDERING CODE
With P2 > P3
With P3 > P2
Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.
The regulated flow rate depends on the inlet flow rate and the oil viscosity.
Flow controlled 1 3 (l/min)
Flow controlled 1 3 (l/min)
Pressure port 3 (bar)
Pressure port 2 (bar)
* Flow rate tolerance: ±15% up to 5 l/
min, ±10% over 5 l/min
** Tolerance on hole ±0.02 mm
** = Code (see table 1)
Table 1
Code
Ø X
(mm) **
Nominal
flow
(l/min) *
05
0.5 0.3
07
0.7 0.7
10
1.0 1.7
12
1.2 2.5
15
1.5 4.0
18
1.8 5.6
20
2.0 7.0
25
2.5 12.2
30
3.0 17.0
The priority flow control valve sends a constant flow from branch 1, first to
priority branch 3 and then the remaining flow to overflow branch 2, regardless
of the downstream oil pressure.
Both branches 2 and 3 can be pressurised.
The flow is reduced by the control hole X which determines the flow rate.
It has a galvanised steel body. The compensator plunger is in tempered and
ground steel.
00012031